CITY
OF SPRINGDALE
Drawings
Required To Finish A Basement Of An Existing
Residence
Into Habitable Space
- Floor plan, drawn to scale, showing:
- Room dimensions
- Room uses
- Window locations and sizes (existing &
proposed)
- Wall framing and firring
(size & spacing)
- Wall finish
- Door locations & sizes
- Ceiling finishes
- Electric outlet, switch lighting locations
- An AC wired smoke detector with battery back-up is required in the
basement and one is required on each floor. On floors where there are
bedrooms, the detector must be inside and outside of the bedrooms.
- Bedrooms are only permitted in basements where an emergency egress
window is provided in the bedroom. This window must have a clear opening
of 24" high minimum and 20" wide minimum with a minimum 5 square
feet opening. The window sill may not be more than 44" from the
floor.